Steps to Import CSV

 Expand...
  1. Go to the collection protocols list page, click on 'Import' button and select option 'Biospecimen Data' OR
  2. Go to participants list page of the CP under which the derived specimens have to be created/updated, click on 'More' button and select option 'Biospecimen Data'
  3. Select 'Specimen Derivatives' from 'Select Record Type' dropdown and click on 'Download Template File' to download the template file
  4. Enter all valid data in the template file as mentioned in the below 'Data Dictionary' table
  5. Upload the filled template file in 'Input Records File' field
  6. Click on 'Validate and Import' button
  7. Refer 'Import status' to check the status of import job

Sample CSV

Download

Data Dictionary

Added in

Column Name

Datatype

Mandatory?


DescriptionPermissible ValuesValidations
v3.3

CP Short Title

StringYesThe collection protocol short title under which specimen is collected
This is mandatory only if specimen labels are not unique across collection protocols. This is a setting user can set in Admin settings. By default labels are unique across the system.

Parent Specimen LabelStringYes

Should label of a collected parent within the system

Specimen LabelStringDependsNeeds to be specified when the auto label generation is OFF or 'Manual Inputs Allowed For' is selected


BarcodeStringNo



ClassStringNo
  • Tissue
  • Molecular
  • Cell
  • Fluid
In v3.4, if left blank system will add class based on specimen type in the input

TypeStringYes
Permissible Values File

Collection StatusStringNo
  • Collected
  • Pending
  • Missed Collection


Pathological Status


No
  • Non-Malignant
  • Non-Malignant, Diseased
  • Pre-Malignant
    Malignant,
  • Pre-Invasive
  • Malignant, Invasive
  • Malignant
  • Metastatic
  • Not Specified


Initial QuantityDoubleNo

Default Value: Not Specified

Available QuantityDoubleNo


v4.2ConcentrationDoubleNoThis field applies only to molecular specimens


Biohazard#1StringNo

Multiple values can be specified as:

Biohazard#1,

Biohazard#2,

Biohazard#3 and so on

  • Hepatitis A
  • Hepatitis B
  • Hepatitis C
  • HIV
  • Tuberculosis
Valid value from the list

Created OnDateNo

Select the correct date format from UI based on the data in the file



Freeze/Thaw Cycles

NumberNoFreeze/Thaw Cycle of the derivative


Increment Parent Freeze/Thaw Cycles

NumberNoNumber by which parent freeze/thaw cycle is to be incremented


Close ParentStringNooptions- Yes/No or true/false
Parent specimen should be in collected -collection status
v5.0CommentsStringNo



Location#ContainerStringNoNeeds to be specified if the specimen is not virtually located
  1. Container specified should be existing
  2. Suitable to hold the specimen (based on type and protocol)
  3. Should have available positions.

Location#RowStringNo

Position within the container at which the specimen is to be stored. If left blank, the system will allocate next available position.


Location#ColumnStringNo

v3.4

Location#Position

NumberNoThe single number or linear position labels to identify slots within the container for storing specimen
  • No labels