This template is used when specimen label auto-generation is on for aliquots. Refer 'Label Configuration' to set label format to auto-generate specimen labels.

Steps to import CSV

 Expand...
  1. Go to the collection protocols list page, click on 'Import' button and select option 'Biospecimen Data' OR
  2. Go to participants list page of the CP under which the aliquot specimens have to be created/updated, click on 'More' button and select option 'Biospecimen Data'
  3. Select 'Specimen Aliquots' from 'Select Record Type' dropdown and click on 'Download Template File' to download the template file
  4. Enter all valid data in the template file as mentioned in the below 'Data Dictionary' table
  5. Upload the filled template file in 'Input Records File' field
  6. Click on 'Validate and Import' button
  7. Refer 'Import status' to check the status of import job

Sample CSV

Download

Data Dictionary

Column Name

Datatype

Mandatory?

(Create)

DescriptionPermissible ValuesValidations
CP Short TitleStringNoThe collection protocol short title under which specimens have to be created
This is mandatory only if specimen labels are not unique across collection protocols. 
Parent Specimen LabelStringYes

Specimen should be existing within the system
Quantity per AliquotDouble

Yes if parent quantity not specified or number of aliquots not specified



If not specified, it divides the entire parent specimen available quantity into equal amounts amongst all the aliquots
Number of AliquotsIntegerYes if parent quantity not specified or quantity per aliquot not specified

When left blank the number of aliquots=(parent quantity/quantity per aliquots)
ContainerStringNoNeeds to be specified if the specimen is not virtually located
  1. Container specified should be existing
  2. Suitable to hold the specimen (based on type and protocol)
  3. Should have available positions.
  4. The specimen gets stored at the next available position within the container
Start RowString or IntegerNoDatatype depending on the row labeling scheme (Numbers, Alphabets Upper Case, Alphabet Lower Case, Roman Upper Case, Roman Lower Case)
Position within the container at which the specimen is to be stored. If left blank, the system will allocate next available position.

Start ColumnString or IntegerNoDatatype depending on the column labeling scheme (Numbers, Alphabets Upper Case, Alphabet Lower Case, Roman Upper Case, Roman Lower Case)
Start PositionNumberNoThe single number or linear position labels to identify slots within the container for storing specimen
Created OnDateNo

Select the correct date format from UI based on the data in the file


Freeze/Thaw CyclesNumberNoFreeze/Thaw Cycle of the aliquot

Increment Parent Freeze/Thaw CyclesNumberNoNumber by which parent freeze/thaw cycle is to be incremented

Close ParentStringNoOptions - Yes/No or true/false
Parent specimen should be in collected- collection status
Specimen Additional Fields#Media VolumeNumberNo


Specimen Additional Fields#Cell Viability (%)NumberNo