Introduction
This document describes how to set up this web service with caTissue to print specimen labels based on the format specified.
...
High level requirements are described below:
...
Parameter | Definition |
---|---|
Specimen Class | Class of the specimen |
Specimen type | Type of the specimen |
Label type | This could be Capcap+ Slide slide or side. This parameter and the specimen type define the information that needs to go in the label. This will help user to configure based on label physical dimensions. |
Data on the label | Information that needs to be included in the label based on the specimen class/type and label type |
Printer | Name of the printer where the request has to be forwarded to. |
Workstation IP | IP address of the machine from where the print request will come and this decides to which printer the request has to be forwarded to. |
Some example entries for this file follow.
Specimen Class | Specimen type | Label type | Data on the label | Printer | Workstation IP |
---|---|---|---|---|---|
Molecular | Any | Cap + Slide | Specimen Label, Specimen type, Concentration | Molecular | IP1 |
Fluid | Any | Cap + Slide | Specimen label, Specimen type | Histology | IP2 |
Cell | Cryopreserved Cells | Cap + Slide | Specimen label | Histology | IP2 |
It can be specified in wild card format like grouping e.g all IPs starting with 128 will have same rule all IPs starting with 128.3. will have same rule |
Below are the APIs present in the application for print rules:
...
Child pages (Children Display) |
---|